3P White/Black Button Type Actuator Hydraulic Magnetic Circuit Breakers equipment protection circuit / 13P White/Black Button Type Actuator Hydraulic Magnetic Circuit Breakers equipment protection circuit / 23P White/Black Button Type Actuator Hydraulic Magnetic Circuit Breakers equipment protection circuit / 3

3P White/Black Button Type Actuator Hydraulic Magnetic Circuit Breakers equipment protection circuit

2024-11-26 15:222350
Price ¥13.82/Piece
Min quantity 10Piece
Quantity 20000Piece

 


CVP-TH Hydraulic-magnetic Circuit Breaker

            is used in AC 230/400V or DC 80V and below power system,rated working current of 0.1-50A,provide protection from overload, short-circuit,also could be used to make and break the circuit not frequently.The breaker could be widely used for equipment provide protection of circuit, power equipment, communication equipment, railway transportation system,telecommunications systems,medical equipment, telecommunication power and UPS equipment and industrial automation system against overload current and short-circuit current.

Specification

Number of Poles

1.2,3.4 poles (optional)

CURRENT RATINGS

AC 0.1-50A(1,2,3&4 Poles)

DC 0.1-50A(1.2.3&4 Poles)

MAXIMUM VOLTAGE

250V AC,277/480V AC,50/60Hz

240V AC,50/60Hz(UL489);80V DC

VOLTAGE COIL

6V DC,12V DC:120V AC

AUXILIARY SWITCH RATING

SPDT;7A,250V AC,7A(Res),28V DC,4A(Ind)0.25A-28V DC,0.1A-125V AC (optional)

INSULATION RESISTANCE

≥100MQ at 500V DC

DIELECTRIC STRENGTH

1500V50/60Hz between terminals for eletrical 50/60Hz

RESISTANCE IMPEDANCE

The value between line and load terminal under ON status

ENDURANCE

Mechanical life is 10k cycles(6 times operation per min.)and electrical life is 6k cycles at rated current and voltage

TRIP-FREE

The circuit breaker will tripped inside even if the handle forcibly held in the ON position when overload

TRIP INDICETlON

Handle is in OFF position when overloaded.For mid-trip,handle is in middle position when overloaded

AII CURVES

Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in standard wall-mount position. On 50 amp and less current ratings the minimum inrush pulse tolerance handling capability is 12 times the rated current on standard delavs and 25 times the rated current on high inrush delays. These values are based on a 60Hz 1/2 cycle, 8.33 ms pulse. High inrush delays should be for applications with high initial surge currents of short duration such as switching power supplies, highly capacitive loads and transformer loads

TEMPERATURE OPERATION

-40'C to +85°C

RECOMMENDED TORQUE

#6-32 or M3 mounting inserts 0.8-1.0 Nm; #8-32 or M4 screw terminals 1.4-1.7 Nm; #10-32 or M5 screw terminals 1.7-2.3 Nm: #1/4-20 or M6 screw terminals 3.4-4.0 Nm

MAXIMUM POLES

4 Poles

MOUNTING TYPE

Snap-in,M3 screw.6-32 screw(optional)

TERMINALS

upturning,screw-in,bus screw-in, flat solder lug type,m6 stud(optional)

ACTUATOR

long handle , short handle, angle rocker, angle rocker(with lock),insert handle, sealed toggle(optional)

COLOR OF CASE

black

STANDARD

EN60934.UL1077.GB17701.UL489A