Share BuyProducts Channel
1/5
WEISEN Copper Power Transformer High Voltage Transformer S11-10kv Oil Immersed Power Transformer / 1WEISEN Copper Power Transformer High Voltage Transformer S11-10kv Oil Immersed Power Transformer / 2WEISEN Copper Power Transformer High Voltage Transformer S11-10kv Oil Immersed Power Transformer / 3

WEISEN Copper Power Transformer High Voltage Transformer S11-10kv Oil Immersed Power Transformer

2025-03-03 16:313410
Price ¥5.00/Piece
Min quantity 10Piece
Quantity 3000Piece

 

Iron core

The iron core is made of cold-rolled grain-oriented silicon steel with high magnetic conductivity, with inclined joint laminated structure. Section of the core limbs is of multi- class ladder round, with uniform section with that of yoke.

Winding

The winding adopts corrugated oil duct with non-dipping process, bound by shrinkable tape; all winding are of concentric coils; taps of HV winding with corresponding tapping voltage shall be led to the tap switch, and the switch shall be installed on the box cover. Power supply must be cut off first when changing the tapping voltage.

Installation of protection device

Transformers of all capacity specifications have been equipped with pressure relief valve.

Gas relay with alarm and tripping terminals is available on request.

Oil-temperature measurement devide

All the transformers are equipped with tube holder for glass-stem thermometer that is set on the top of oil tank,and immersed in oil for about 120 ± 10 mm

1000~2000 kVA transformer is equipped with outdoor signal thermometer

Transformer oil tank

Transformer oil tank is corrugated of corrugated walls with powder painted surface and reinforced and reinforced with film. Corrugated cooling fin not only has cooling function, but also has "breathing" function, the elasticity of corrugated cooling fin make it adapt to the change of oil volume due to change of temperature. So this hermetically does not conservator, which decreases the height of transformer.

The transformer adopts vacuum oil-injection technology during encapsulation that thoroughly removes the moisture from transformer, and keeps the transformer oil from contacting the air. This technology also avoid insulation performance reduction or oil aging due to entering of oxygen or moisture, it improves operation reliability of transformer.

Main technical parameters

Service conditions

Installation height: altitude shall not exceed 1000m

Ambient temperature:-40℃~40℃

Size Slection

    

Hate 0