Packaging & delivery
Packaging Details
Each unit has original individual box, all boxes are packed in standard packages.
Port
Shanghai
Lead time:
Quantity(pieces) 1 - 50 51 - 200 >200 Lead time (days) 5 8 To be negotiated
JXK14 open loop hall effect current sensor with ce high accuracy current transducer 0-10v
Introduction
<1>Working principle: open loop direct measurement.
<2>Product uses: Used for measuring DC, AC, pulse current and other arbitrary waveform current.
<3>Product advantages: Better cost performance, low power consumption, small volume, light weight, easy installation, perforation input and no insertion loss.
<4>Product application: Frequency conversion speed control system, electric welding machine, electrochemistry, power supply monitoring, electric locomotive, low level starting protection.
The input, output, power and outer shell are isolated, with strong anti-interference ability and high reliability.Full channel configuration,Parameter customizable.
Technical Parameter
Input | |
Original Side Rated Input current | 10A;20A;50A;100A; 200A;customization |
Original Side Measurement Range | 20A-300A |
Output | |
Rated Output | 55V;10V;DC4-20mA;0-20mA |
Other Parameters | |
Installation | The standard rail +Plane screw fixation |
Auxiliary Power Supply | ±12V;±15V;DC12V;DC24V |
Load Capacity | 5mA |
Linearity | 0.5% |
Accuracy | 1% F.S. |
Overload Capacity | Double nominal input, sustainable |
Response time | <200ms |
Temperature drift | ≤500PPM/℃ |
Band Width | DC~20KHz |
Consumption of Current | ≤25mA |
Insulation resistance | ≥100MΩ (among input-ouput-power) |
Working Temperature | -10℃~+70℃ |
Storage Temperature | -25℃~+85℃ |
Isolation Pressure Resistance | 2.5kV/50Hz,1Min |
Offset Voltage | ≤20Mv |
Product Selection
Wiring Diagram
Product Display